Top 12 Green-IT Users: No. 1 Highmark Inc.

February 15, 2008 12:00 PM ET

Computerworld - From cars to condos, "green" is all the rage these days — and IT is no exception. Eco-friendly computing promises the twin win of saving money and the environment. In this groundbreaking awards program,Computerworld honors 12 user companies and another dozen vendors that are leading the way (see the full list of honorees).

These green leaders are virtualizing, videoconferencing, turning down the cooling systems and turning off the lights. Want to see how your organization stacks up with the winners? Take our quiz to find out how green your company is now, and how to make it even greener. Also, read how the "Green Dozen" were chosen, view the full survey completed by the participants and see our list of the greenest technology vendors and data center suppliers.

This year's #1 green IT company: Highmark

Highmark Inc. spent about $45,000 each month on electricity in its old data center, a 24,000-square-foot, Tier 1 facility in Camp Hill, Pa.

The company's new data center, built entirely of recycled building materials and certified as a leader in energy and environmental design by the U.S. Green Building Council, is an 86,000-square-foot, Tier 3 facility with some 28,000 feet of raised flooring. The new data center is three times bigger than the old one, but its electricity costs are the same: $45,000 per month.

Thanks to an array of energy- conserving technologies — including server virtualization and next-generation air- and equipment-cooling proc-esses — the medical insurer has not only kept its energy costs in check, but has also expanded operations and increased production since building the data center in 2005.

Now the goal is to decrease power usage companywide. For IT specifically, the target reduction is 5% this year. Currently, the company's main data center in Harrisburg uses about 700 kilowatts of electricity per month — enough to power 175 homes, says Mark Wood, director of data center infrastructure.

Highmark will pay 6.5 cents per kilowatt until 2010, when rate caps come off. But after that, "we're expecting a 20% to 30% increase in energy costs," says Wood. "Anything we can do now to reduce consumption will lower that."

Highmark began virtualizing servers last year, replacing about 100 of them with virtualized machines. IT also has migrated its Lotus Notes mail system from servers to an existing mainframe, using previously unused mainframe capacity to support e-mail at the 12,000-person company. IT will keep working on server virtualization this year, Wood says, but that's only a start. "Now we need to look at disk virtualization, and we need to go to de-duplication of data to save [disk storage] space," he adds.

Highmark has taken a unique approach to the challenge of cooling equipment in the data center, where it recirculates the air to keep temperatures down. "The air handlers on the floor push cold air under the raised floor. We then pull that air through the front door of our 19-inch [server] racks as part of our cooling system," Wood says. "We have monitors inside each rack that speed up or slow down fans based on the amount of heat it generates."

More Info

Highmark's Tom Tabor, CIO, and Mark Wood, director of data center infrastructure
Photo credit: Chris Hartlove

Location: Harrisburg, PA
Website: www.highmark.com
What's special: Pushes cold air under a raised floor in the data center to cool server racks, which are equipped with monitors to regulate fans, based on the amount of heat generated.
What's cheap: Collects rain runoff from the roof to cool equipment.

Another unique energy-conserving feature is a 100,000-gallon water tank underneath the data center. Highmark uses the tank to collect rainwater that runs off the roof and then uses the water to cool the data center, which evaporates water at a rate of about 12 gallons a day. "Everybody always thinks about energy, but water is just as valuable, because without water, you can't cool equipment," Wood notes.

Forrester Research Inc. analyst Christopher Mines says Highmark is "ahead of the pack in even looking at this dimension of the [cooling] problem. Virtually every company I talk to is focused on electricity usage" and maybe the resulting carbon emissions, he adds.

Highmark CIO Tom Tabor partially attributes Highmark's leadership status on the green-IT front to good timing. "We've had an opportunity to provide leadership as a result of building the data center at the right time," he says.

It's also fitting for IT to be the leader within the company. "The data center consumes more power than anywhere else in the organization," Tabor says. "Highmark is an organization that runs on information, and our data center is the guts of the organization."

Next: No. 2 Discovery Communications LLC

Read more about servers and data center in Computerworld's Servers and Data Center Knowledge Center.



Jump to comments

Green IT

Additional Resources

EFD vs. HDD - What You Need to Know
WHITE PAPER
Enterprise flash drives provide a new Tier 0 storage layer capable of delivering high I/O performance at a very low latency. Proper use of EFDs in an Oracle environment can deliver increased performance compared to fibre channel drives. Read the recommendations for identification of the best DB components for EFDs.
Gartner Research Report: Magic Quadrant for Application Delivery Controllers, 2009
WHITE PAPER
The market for products to improve the delivery of application software over networks remains dynamic and innovative. Vendors focused on solving enterprises' most-pressing application problems have become the top players.
Eight Criteria for Server Load Balancing
WHITE PAPER
Server load balancers are a simple yet highly effective means to scale an application environment while ensuring its availability. Today's solutions should also address application performance and security. Read about the top eight criteria you should consider when choosing a server load balancer and how Citrix NetScaler meets those requirements.

What People Are Saying

White Papers & Webcasts

The Business Case for Virtualization
Download this Resource Now!  

Effectively Implementing Datacenter Automation
Effectively select and deploy the best datacenter automation solution today!

XenApp Extends Virtualized Application Delivery
Download this webcast to learn how to accelerate delivery of virtualized applications and streamline management.

Top HPC Use Cases in Life Sciences
Learn from the experts how best to apply cutting edge high-performance computing techniques a life sciences environment.


IT Jobs